The heated reactor should be operated strictly according to the working pressure and working temperature marked on the product nameplate to avoid danger. And strictly abide by the provisions of the product manual for cooling, oiling, etc., and do a good job in maintenance and maintenance of the equipment.

 

When all the valves of the heating reactor are used, the valve stem should be rotated slowly to press the cover tightly to achieve the sealing effect. Do not use excessive force when closing, so as not to damage the sealing surface. The electric control instrument of the heating reactor should be operated by a special person and the overload protection facilities should be set as required.

 

When the leakage occurs at the sealing surface of the heating reactor, the screw is tightened again, and the polishing sealing surface is re-grinded; when the valve leaks, the valve stem (needle) and the valve port are repaired; the outer magnetic steel rotates, and the inner magnetic steel does not rotate. When the motor current decreases, notify the supplier to replace the inner magnetic steel. When there is friction noise in the magnetic coupling actuator, contact the supplier to replace the bearing and bushing.http://wxlsshzb.com/